HSDPA User Equipment (UE) categories

Это HSDPA категории пользовательскихъх терминалов. Источником является стандарт 3GPP TS 25.306 V12.4.0 (2014-12).

HS-DSCH category Downlink throughput, Mbps Maximum number of HS-DSCH codes received Maximum number of bits of an HS-DSCH transport block received within an HS-DSCH TTI NOTE 1 Total Number of serving/secondary serving HS-DSCH cells
Category 1 7.3 5 7298 1
Category 2 7.3 5 7298 1
Category 3 7.3 5 7298 1
Category 4 7.3 5 7298 1
Category 5 7.3 5 7298 1
Category 6 7.3 5 7298 1
Category 7 14.4 10 14411 1
Category 8 14.4 10 14411 1
Category 9 20.3 15 20251 1
Category 10 28 15 27952 1
Category 11 3.6 5 3630 1
Category 12 3.6 5 3630 1
Category 13 35.3 15 35280 1
Category 14 42.2 15 42192 1
Category 15 23.4 15 23370 1
Category 16 28 15 27952 1
Category 17 NOTE 2 35.3 15 35280 1
23.4 23370 1
Category 18 NOTE 3 42.2 15 42192 1
28 27952 1
Category 19 35.3 15 35280 1
Category 20 42.2 15 42192 1
Category 21 23.4 15 23370 2
Category 22 28 15 27952 2
Category 23 35.3 15 35280 2
Category 24 42.2 15 42192 2
Category 25 23.4 15 23370 2
Category 26 28 15 27952 2
Category 27 35.3 15 35280 2
Category 28 42.2 15 42192 2
Category 29 42.2 15 42192 3
Category 30 42.2 15 42192 3
Category 31 42.2 15 42192 4
Category 32 42.2 15 42192 4
Category 33 42.2 15 42192 6
Category 34 42.2 15 42192 6
Category 35 42.2 15 42192 8
Category 36 42.2 15 42192 8
Category 37 42.2 15 42192 2
Category 38 42.2 15 42192 4

NOTE 1:   A UE of category 25 supports the physical capabilities of categories 18. The first row of category 25 in table 5.1c specifies the capabilities when MIMO is not configured and the capabilities of category 18 apply .The second row of category 25 in table 5.1c specifies the capabilities when MIMO is configured.

NOTE 2:   A UE of category 17 supports the physical capabilities of categories 13 and 15, but not simultaneously. The first row of category 17 in table 5.1a specifies the capabilities when MIMO is not configured and the capabilities of category 13 apply, the second row specifies the capabilities when MIMO is configured and the capabilities of category 15 apply.NOTE 1:   Depending on the HS-DSCH configuration, the indicated maximum number of bits of an HS-DSCH transport block does not have to correspond exactly to an entry in the transport block size table to be applied [9].

NOTE 3:   A UE of category 18 supports the physical capabilities of categories 14 and 16, but not simultaneously. The first row of category 18 in table 5.1a specifies the capabilities when MIMO is not configured and the capabilities of category 14 apply, the second row specifies the capabilities when MIMO is configured and the capabilities of category 16 apply.

Обсуждение закрыто.